Education Code section 17285
(a)
Notwithstanding any provision of law except Section 17286, 17287, 17405, and this section, a leased building that does not meet the requirements of Section 17280 may not be used as a school building, as defined in Section 17283, after September 1, 1990.(b)
A school district may lease a commercial building prior to January 1, 2003, that does not meet the requirements of Section 17280, for use as a school building, as defined in Section 17283, if the governing board of the district finds that all of the following conditions have been met:(1)
The building was constructed in accordance with seismic safety standards for commercial buildings constructed within an earthquake zone.(2)
The building permit for the initial construction of the building was issued on or after January 1, 1990.(3)
A structural engineer has inspected the building and submitted a report to the governing board of the school district that certifies that the building is in substantial compliance with the requirements of the Field Act. This certification requirement is satisfied if the structural engineer affixes his or her seal of approval to the report and he or she attests in that report that to the best of his or her knowledge:(A)
He or she has reviewed the design calculations, construction documents, and the local government construction inspection records of the building to the extent available.(B)
He or she has authorized testing and has observed or reviewed the test results and the inspections of an adequate sample of the structure’s welds, anchor bolts, and other structural elements.(C)
He or she has observed that the overhead nonstructural elements, including, but not limited to, light fixtures, heating, and air-conditioning diffusers are adequately braced or anchored.(c)
A building leased pursuant to Section 17280 may be used after September 1, 1991, as a regional occupational center or program that does not meet the requirements of Section 17280, provided the building satisfies all of the following conditions:(1)
The facility is one of the following:(A)
A single-story, wood-framed structure.(B)
A single-story, light steel frame structure.(C)
A structure for which a structural engineer has submitted a report that certifies that substantial structural hazards do not exist, as to that structure. The governing board of the regional occupational center or program, as provided for under Section 52310.5, shall review the report prior to approval of the lease and may reject the report if there is any evidence of fraud regarding the facts in the report.(2)
The building or structure complies with all applicable local building standards and all applicable local health and safety standards in the community in which it is located.(3)
The governing board of the regional occupational center or program, as provided for under Section 52310.5, certifies to the State Allocation Board that reasonable efforts have been made to locate the regional occupational center or program in facilities that conform to the seismic safety standards set forth in Part 2 (commencing with Section 2-101), Part 3 (commencing with Section 3-089-1), Part 4 (commencing with Section 4-403), and Part 5 (commencing with Section 5-102), of Title 24 of the California Code of Regulations.